• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
teknoversite
View Item 
  •   DSpace Home
  • Araştırma Çıktıları | TR - Dizin
  • Araştırma Çıktıları | TR-Dizin İndeksli Yayınlar Koleksiyonu
  • View Item
  •   DSpace Home
  • Araştırma Çıktıları | TR - Dizin
  • Araştırma Çıktıları | TR-Dizin İndeksli Yayınlar Koleksiyonu
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Investigation on limitation of reduced relative storey drifts according to TEC 2007

Thumbnail

View/Open

Tam Metin / Full Text (650.3Kb)

Date

2018

Author

Erdem, Muhammet Musab
Bikçe, Murat

Metadata

Show full item record

Citation

Erdem, M.M., Bikçe, M. (2018). Investigation on limitation of reduced relative storey drifts according to TEC 2007. International Advanced Researches and Engineering Journal, 2(3), 223-228.

Abstract

During the earthquake motion, limitation of storey drifts of is important. Maximum storey driftsfor the structures to be constructed in our country has been restricted by Turkish EarthquakeCode (TEC) which is in force since 2007, according to the provision of relative storey drift andA1, A2 irregularity factors. In the earthquake code which is published as draft in 2016 and is notin force yet, it has been planning to restrict the storey drifts for with and without gap conditionsof infill wall - frame connections. First of all, it is aimed to investigate the limits of maximumreduced relative storey drift under specified conditions according to TEC 2007. In this study, themaximum values of allowable reduced storey drifts were specified separately for reinforcedconcrete buildings which have 2.75m – 4.25m storey height interval, according to limitationsspecified in section of TEC 2007 that is “Calculation and Limitation of Effective Relative StoreyDrifts” for each of the Structural System Behavior Factors (R). Additionally, as an example,maximum relative story drifts have calculated according to “A1- Torsional Irregularity” sectionof TEC 2007 by using the relative storey drifts which belongs to a building from literature, andfor this building, maximum relative storey drifts has calculated according to “B2- InterstoreyStiffness Irregularity” section of TEC 2007 for variable interstorey heights. At the end of thestudy, maximum values of relative storey drifts in the floor have revealed according to averagestorey drifts and storey height ratios.

Source

International Advanced Researches and Engineering Journal

Volume

2

Issue

3

URI

http://www.trdizin.gov.tr/publication/paper/detail/TXpNMk5qZzVPUT09
https://hdl.handle.net/20.500.12508/1012

Collections

  • Araştırma Çıktıları | TR-Dizin İndeksli Yayınlar Koleksiyonu [214]
  • Makale Koleksiyonu [85]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Instruction | Guide | Contact |

DSpace@İSTE

by OpenAIRE
Advanced Search

sherpa/romeo
Dergi Adı / ISSN Yayıncı

Exact phrase only All keywords Any

Başlık İle Başlar İçerir ISSN


Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeDepartmentPublisherCategoryLanguageAccess TypeİSTE AuthorIndexed SourcesThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeDepartmentPublisherCategoryLanguageAccess TypeİSTE AuthorIndexed Sources

My Account

LoginRegister

Statistics

View Google Analytics Statistics

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Guide|| Instruction || Library || Iskenderun Technical University || OAI-PMH ||

Iskenderun Technical University, İskenderun, Turkey
If you find any errors in content, please contact:

Creative Commons License
Iskenderun Technical University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@İSTE:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.