Ara
Toplam kayıt 27, listelenen: 11-20
The investigation of K-shell fluorescence parameters of Zn-Fe alloys with different grain size and microstrain values
(Wiley, 2017)
It is known that zinc alloys with iron group metals have better corrosion resistance than pure zinc. Owing to the corrosion resistance of these alloys, Zn-Fe coatings are widely used in automotive industry and have excellent ...
Review of experimental photon-induced Kβ/Kα intensity ratios
(Academic Press Inc Elsevier Science, 2020)
In this paper, we present a compilation of the measured photon-induced K-beta/K-alpha intensity ratio values published in the literature from 1969 to 2018. In the considered period, we found about 1118 values (127 papers) ...
L-1, L-2, and L-3 subshell fluorescence yields: Updated database and new empirical values
(Elsevier, 2016)
In this paper, a summary of experimental data published in the period of time between 1955 to february-2016 was presented in a tabular form for L, subshell fluorescence yields (omega(L1), omega(L2) and omega(L3)) taken ...
Empirical K-Shell Production Cross Sections Induced by 2-5 MeV Alpha on Elements of Z= 25 to 30
(American Institute of Physics Inc., 2018)
During the last decades, the study of phenomena occurring in collisions between charged particles and target atoms has grown to a field of increasing interest in both its theoretical and experimental aspects. This growing ...
Synthesis, electrochromic characterization and solar cell application of thiophene bearing alternating copolymers with azobenzene and coumarin subunits
(Taylor & Francis, 2020)
In this study, azobenzene and coumarin functionalized thiophene comprising two copolymers (poly (4-((3"'-hexyl-[2,2 ':5 ',2 '':5 '',2"'-tetrathiophene] - 3 '-yl)methoxy) - 2H-chromen-2-one (P1) and poly (1-(4-((4"'-hexyl-[2,2 ...
The semi-empirical determination of KLL Auger, Kα1 and Kα2 X-ray line widths for sulfur atom in new 1,2,4-triazol compounds containing thiophene ring
(Elsevier Science, 2018)
In this study K-alpha 1, K-alpha 2 and KLL Auger line widths were determined semi-empirically by using K shell fluorescence yields of sulfur even if K-alpha X-ray lines cannot be resolved in our detector system. The samples ...
The Semi-Empirical Determination of Kα X-ray, KLL Auger Line and L subshell level widths for 3d transition elements at 59.5 keV
(Celal Bayar Üniversitesi, 2019)
The emission of X-rays in Ka and KLL Auger energy regions were analyzed for transition metals by using energy dispersive X-ray fluorescence (EDXRF) system. To acquire more information in this energy region, the semi-empirical ...
A dynamic model of air-breathing polymer electrolyte fuel cell (PEFC): A parametric study
(Elsevier, 2021)
A dynamic model for an air-breathing PEFC has been built to investigate the transient response of the fuel cell to load changes. The sensitivities of the dynamic response, as well as the steady state performance, to: the ...
M Shell Fluorescence Parameters of Pt, Au and Tl Compounds with Oxygen and Bromide
(Adıyaman University, 2019)
In this study, Mβα X-ray production cross-sections and average M-shell fluorescence yields were determined by using EDXRF at 5.96 keV for Pt, Au and Tl compounds. The photo-peak areas were used for the measurement of M ...
Microhydrogen production with water splitting from daily used waste aluminum
(Elsevier, 2021)
In this study, different types of waste aluminum produced in daily life and their pure equivalents were evaluated and compared in terms of their hydrogen generation performance through the water-splitting reaction. An ...