Ara
Toplam kayıt 23, listelenen: 1-10
ÇBAG kullanılan rüzgar türbinlerinin güç kontrol döngüsüne hassasiyet ve sağlamlık analizi uygulanması
(Dicle Üniversitesi, 2017)
Bu makalede, çift beslemeli asenkron generatör (ÇBAG) kullanılan rüzgar türbinlerinin stator güç denklemleri kullanılarak güç kontrol modeli elde edilmiş ve kontrolünde iyileştirmeler sağlanmıştır. Genellikle, rotor ...
Yeni Bir Yüksek Hızlı Kalp Destek Pompasının Sayısal ve Deneysel Analizi
(2018)
Sol ventriküler destek cihazları kalp yetmezliğine sahip hastalarda kullanılmaktadır. Rotodinamikkan pompalarının santrifüj, eksenel ve karışık akışlı olmak üzere üç tipi vardır. Eksenel akışlı kanpompaları yüksek hızlı ...
Updated database, new empirical and theoretical values of average L shell fluorescence yields of elements with 23 <= Z <= 96
(Pergamon-Elsevier Science Ltd, 2020)
In this paper, a summary of existing experimental data published in the period of time between 1954 and 2015 is reviewed and presented in a tabular form for average L shell fluorescence yields taken from different sources. ...
Structure Effect on K Shell Fluorescence Parameters at Bis-4-Bromobenzyl-1,2,4-Triazol-3-Ones
(Office Spectroscopy and Spectral Analysis, 2016)
In this study; the effect of the electron density over the Br atoms raising with increasing number of CH2 group using the results of the K X-ray cross-sections and average fluorescence yields of bromine in quaternary-imidazole ...
Enhancing electrochemical and electrochromic performances of carbazole comprising monomer via copolymerization with 3,4-ethylenedioxythiophene (EDOT)
(Elsevier, 2020)
In this study, two novel electrochromic copolymers (CoP1.3 and CoP1.5) were synthesized via electrochemical methods and characterized. The comonomers used in the synthesis were 3,4-ethylenedioxythiophene (EDOT) and a ...
Semi-empirical determination of Kα1,2, Kβ1,3, and Kβ2,4 X-ray natural line widths for various elements between 29 ≤ Z ≤ 74 at 123.6 keV
(Taylor & Francis Inc, 2019)
In this study, K-alpha 1,K-2, K-beta 1,K-3, and K-beta 2,K-4 X-ray natural line widths for various elements were determined semi-empirically at 123.6 keV by using K shell fluorescence yields obtained from energy dispersive ...
Enhancement of image quality by using metamaterial inspired energy harvester
(Elsevier, 2020)
Metamaterial energy harvester based subwavelength imaging structure is presented. Besides, 2x2 array patch antenna is designed to create incident radiated signal towards the proposed harvester structure. Harvested energy ...
Polarization independent broadband metamaterial absorber for microwave applications
(John Wiley and Sons Inc., 2019)
A new polarization independent broadband metamaterial absorber (MA) structure based on split ring resonators which are loaded with lumped elements and via connection lines is proposed. The designed structure shows a perfect ...
The investigation of K-shell fluorescence parameters of Zn-Fe alloys with different grain size and microstrain values
(Wiley, 2017)
It is known that zinc alloys with iron group metals have better corrosion resistance than pure zinc. Owing to the corrosion resistance of these alloys, Zn-Fe coatings are widely used in automotive industry and have excellent ...
L-1, L-2, and L-3 subshell fluorescence yields: Updated database and new empirical values
(Elsevier, 2016)
In this paper, a summary of experimental data published in the period of time between 1955 to february-2016 was presented in a tabular form for L, subshell fluorescence yields (omega(L1), omega(L2) and omega(L3)) taken ...