• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
teknoversite
View Item 
  •   DSpace Home
  • Fakülteler
  • Mühendislik ve Doğa Bilimleri Fakültesi
  • Elektrik-Elektronik Mühendisliği
  • Makale Koleksiyonu
  • View Item
  •   DSpace Home
  • Fakülteler
  • Mühendislik ve Doğa Bilimleri Fakültesi
  • Elektrik-Elektronik Mühendisliği
  • Makale Koleksiyonu
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Chiral metamaterial-based sensor applications to determine quality of car lubrication oil

Date

2021

Author

Dalgaç, Şekip
Karadağ, Faruk
Bakır, Mehmet
Akgöl, Oğuzhan
Ünal, Emin
Karaaslan, Muharrem

Metadata

Show full item record

Citation

Dalgaç, Ş., Karadağ, F., Bakır, M., Akgöl, O., Ünal, E., Karaaslan, M. (2021). Chiral metamaterial-based sensor applications to determine quality of car lubrication oil. Transactions of the Institute of Measurement and Control, 43 (7), pp. 1640-1649. https://doi.org/10.1177/0142331220976104

Abstract

Motor oils have to be changed periodically in a period of 10.000-20.000 km according to the motor types. A chiral metamaterial sensor that operates in X band is developed to determine the quality of motor oils, numerically analyzed and experimentally tested in this study. The proposed design has square and circular shaped resonators that are printed on IS680 substrate. Reflection coefficient parameters of S-11 and S-22 are employed for the verification of sensor. The physical principle behind the structure in this study is based on the degradation of motor oil, which changes dielectric constant and causes resonance frequency shifts. According to S-11 reflection coefficient data, 40 MHz(0 km-10000 km) and 60 MHz(0 km-5000 km) resonant frequency shifts are observed between clear and dirty motor oils samples. These shifts have the values of 30 MHz(0 km-10000 km) and 120 MHz(0 km-5000 km), when we look at S-22. The simulated and experimental study results are complying with each other. The novel side of this study is to have high sensitivity and higher quality factor when it is compared with similar study results. Furthermore, no such studies have been conducted so far in the literature.

Source

Transactions of the Institute of Measurement and Control

Volume

43

Issue

7

URI

https://doi.org/10.1177/0142331220976104
https://hdl.handle.net/20.500.12508/1738

Collections

  • Araştırma Çıktıları | Scopus İndeksli Yayınlar Koleksiyonu [1057]
  • Araştırma Çıktıları | Web of Science İndeksli Yayınlar Koleksiyonu [1070]
  • Makale Koleksiyonu [202]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Instruction | Guide | Contact |

DSpace@İSTE

by OpenAIRE
Advanced Search

sherpa/romeo
Dergi Adı / ISSN Yayıncı

Exact phrase only All keywords Any

Başlık İle Başlar İçerir ISSN


Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeDepartmentPublisherCategoryLanguageAccess TypeİSTE AuthorIndexed SourcesThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeDepartmentPublisherCategoryLanguageAccess TypeİSTE AuthorIndexed Sources

My Account

LoginRegister

Statistics

View Google Analytics Statistics

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Guide|| Instruction || Library || Iskenderun Technical University || OAI-PMH ||

Iskenderun Technical University, İskenderun, Turkey
If you find any errors in content, please contact:

Creative Commons License
Iskenderun Technical University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@İSTE:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.