• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
teknoversite
View Item 
  •   DSpace Home
  • Araştırma Çıktıları | Web of Science
  • Araştırma Çıktıları | Web of Science İndeksli Yayınlar Koleksiyonu
  • View Item
  •   DSpace Home
  • Araştırma Çıktıları | Web of Science
  • Araştırma Çıktıları | Web of Science İndeksli Yayınlar Koleksiyonu
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Molecularly imprinted QCM sensor based on delaminated MXene for chlorpyrifos detection and QCM sensor validation

Thumbnail

View/Open

Tam Metin / Full Text (3.958Mb)

Date

2020

Author

Kadirsoy, Selcen
Atar, Necip
Yola, Mehmet Lütfi

Metadata

Show full item record

Citation

Kadirsoy, S., Atar, N., Yola, M.L. (2020). Molecularly imprinted QCM sensor based on delaminated MXene for chlorpyrifos detection and QCM sensor validation. New Journal of Chemistry, 44(16), 6524-6532. https://doi.org/10.1039/d0nj00951b

Abstract

Chlorpyrifos (CHL) is one of the most frequently used broad-spectrum organophosphate insecticides. Especially, its incorrect and uncontrolled usage cause public concern about food and environment safety. In this report, a new molecularly imprinted quartz crystal microbalance (QCM) sensor on delaminated sulfur-doped MXene (d-S-Ti3C2TX MXene) was prepared for CHL. The structures of the bare MAX phase (Ti3AlC2), sulfur-doped MAX phase (S-Ti3AlC2), wrinkled sulfur-doped MXene (S-Ti3C2TX MXene) and d-S-Ti3C2SX MXene were highlighted by scanning electron microscopy (SEM), transmission electron microscopy (TEM), atomic force microscopy (AFM), X-ray photoelectron spectroscopy (XPS), Fourier transform infrared spectroscopy (FTIR), electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and X-ray diffraction (XRD). The CHL imprinted QCM sensor was prepared in the presence of MAGA and CHL in 2 : 1 molar ratio. From the analytical results 1.0 x 10(-12)-1.0 x 10(-10) M and 3.0 x 10(-13) M were found to be the linearity range and detection limit (LOD), respectively. Furthermore, the CHL imprinted QCM sensor was examined in terms of stability, repeatability, reproducibility and reusability. Finally, the imprinted sensor was applied to orange juice samples, and a high recovery was obtained.

Source

New Journal of Chemistry

Volume

44

Issue

16

URI

https://doi.org/10.1039/d0nj00951b
https://hdl.handle.net/20.500.12508/1110

Collections

  • Araştırma Çıktıları | Scopus İndeksli Yayınlar Koleksiyonu [1420]
  • Araştırma Çıktıları | Web of Science İndeksli Yayınlar Koleksiyonu [1460]
  • Makale Koleksiyonu [89]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Instruction | Guide | Contact |

DSpace@İSTE

by OpenAIRE
Advanced Search

sherpa/romeo
Dergi Adı / ISSN Yayıncı

Exact phrase only All keywords Any

Başlık İle Başlar İçerir ISSN


Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeDepartmentPublisherCategoryLanguageAccess TypeİSTE AuthorIndexed SourcesThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeDepartmentPublisherCategoryLanguageAccess TypeİSTE AuthorIndexed Sources

My Account

LoginRegister

Statistics

View Google Analytics Statistics

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Guide|| Instruction || Library || Iskenderun Technical University || OAI-PMH ||

Iskenderun Technical University, İskenderun, Turkey
If you find any errors in content, please contact:

Creative Commons License
Iskenderun Technical University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@İSTE:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.