• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
teknoversite
View Item 
  •   DSpace Home
  • Araştırma Çıktıları | Web of Science
  • Araştırma Çıktıları | Web of Science İndeksli Yayınlar Koleksiyonu
  • View Item
  •   DSpace Home
  • Araştırma Çıktıları | Web of Science
  • Araştırma Çıktıları | Web of Science İndeksli Yayınlar Koleksiyonu
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Interline fuel cell (I-FC) system with dual-functional control capability

Thumbnail

View/Open

Tam Metin / Full Text (3.386Mb)

Date

2020

Author

İnci, Mustafa

Metadata

Show full item record

Citation

İnci, Mustafa. (2020). Interline fuel cell (I-FC) system with dual-functional control capability. International Journal Of Hydrogen Energy. 45(1), 891-903. https://doi.org/10.1016/j.ijhydene.2019.10.122

Abstract

In this paper, a new system concept is presented for the grid connection of fuel cells. In conventional grid-connected systems, fuel cells ensure the generated power into a single electrical feeder and control the electrical-line through interfacing elements. In the proposed system, interline fuel cell (I-FC) system shares a common dc-dc converter tied fuel cell at the base of inverters and eliminates the additional fuel cell & dc-dc converter in a multi-feeder system. For this purpose, a fuel cell system is connected to multi-feeders through separate inverters, thereby sharing electrical power into the feeders and attenuating the harmonics at grid-side currents. In this direction, the proposed system presents an economical way for the mitigation of electrical problems for multi-feeders. In order to achieve the functional capabilities of I-FC system, dual-functional control is separately applied in the grid inverters. In the testing stage of I-FC, nonlinear loads in feeder I & feeder II create 31.29% and 27.61% total harmonic distortion (THD) at grid-side currents, respectively. With I-FC, the THD values are reduced to approximately 3% values in both feeders after the harmonic elimination capability. Also, I-FC allocates the active power to both feeders, and reduces the electrical power demand from the utility-grids. The evaluation results verify that I-FC system accomplishes the good performance to control power-sharing and attenuate the current harmonics at grid-side. (C) 2019 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.

Source

International Journal Of Hydrogen Energy

Volume

45

Issue

1

URI

https://doi.org/10.1016/j.ijhydene.2019.10.122
https://hdl.handle.net/20.500.12508/1146

Collections

  • Araştırma Çıktıları | Scopus İndeksli Yayınlar Koleksiyonu [1426]
  • Araştırma Çıktıları | Web of Science İndeksli Yayınlar Koleksiyonu [1467]
  • Makale Koleksiyonu [78]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Instruction | Guide | Contact |

DSpace@İSTE

by OpenAIRE
Advanced Search

sherpa/romeo
Dergi Adı / ISSN Yayıncı

Exact phrase only All keywords Any

Başlık İle Başlar İçerir ISSN


Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeDepartmentPublisherCategoryLanguageAccess TypeİSTE AuthorIndexed SourcesThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeDepartmentPublisherCategoryLanguageAccess TypeİSTE AuthorIndexed Sources

My Account

LoginRegister

Statistics

View Google Analytics Statistics

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Guide|| Instruction || Library || Iskenderun Technical University || OAI-PMH ||

Iskenderun Technical University, İskenderun, Turkey
If you find any errors in content, please contact:

Creative Commons License
Iskenderun Technical University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@İSTE:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.