Soil Based Design of Highway Guardrail Post Depths Using Pendulum Impact Tests

Thumbnail

View/Open

Tam Metin / Full Text (2.262Mb)

Date

2019

Author

Örnek, Murat
Atahan, Ali Osman
Türedi, Yakup
Erdem, Muhammet Musab
Büyük, Murat

Metadata

Show full item record

Citation

Örnek, M., Atahan, A.O., Türedi, Y., Erdem, M.M., Büyük, M. (2019). Soil based design of highway guardrail post depths using pendulum impact tests. Acta Geotechnica Slovenica, 16 (2), pp. 77-89. https://doi.org/10.18690/actageotechslov.16.2.77-89.2019

Abstract

Guardrails are passive road restraint systems (RRS) used at roadsides and medians to improve road safety. In the case of inadequate post embedment depth of soil driven posts may not function as intended and design cannot provide adequate safety nor security for the impacting vehicles. In general, the height of the steel guardrails varies between 1600 and 2400mm. However, the characteristics of the soil where the guardrails are driven are not taken into consideration. In other words, a constant depth ofguardrail is used regardless of the type of soil. Post embedment depths (PED) in steel guardrail systems are currently determined based on strong soil properties. The crash performance of these designs may not be appropriate for locations where soil conditions are weaker than tested conditions. In this study, a series offield impact tests were performed on soil embedded posts to determine optimum PED for three different soil conditions, namely hard, medium hard and soft soil. A pendulum device is used to perform dynamic impact tests on C type (C120x60x4), H type (H150x90x6) and S type (S100x50x4.2) posts. Seven different PED values were used for each type of soil. A total of 63 impact tests proved that increased soil stiffness resulted reduction in PED for the posts. Optimum PED values are determined based on energy absorption of posts. With the use of optimum length guardrail posts considerable amount of installation time, labor and material savings are expected.

Source

Acta Geotechnica Slovenica

Volume

16

Issue

2

URI

https://doi.org/10.18690/actageotechslov.16.2.77-89.2019
https://hdl.handle.net/20.500.12508/1228

Collections

  • Araştırma Çıktıları | Scopus İndeksli Yayınlar Koleksiyonu [1426]
  • Araştırma Çıktıları | Web of Science İndeksli Yayınlar Koleksiyonu [1467]
  • Makale Koleksiyonu [193]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Instruction | Guide | Contact |

DSpace@İSTE

by OpenAIRE
Advanced Search

sherpa/romeo
Dergi Adı / ISSN Yayıncı

Exact phrase only All keywords Any

Başlık İle Başlar İçerir ISSN


Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeDepartmentPublisherCategoryLanguageAccess TypeİSTE AuthorIndexed SourcesThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeDepartmentPublisherCategoryLanguageAccess TypeİSTE AuthorIndexed Sources

My Account

LoginRegister

Statistics

View Google Analytics Statistics

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Guide|| Instruction || Library || Iskenderun Technical University || OAI-PMH ||

Iskenderun Technical University, İskenderun, Turkey
If you find any errors in content, please contact:

Creative Commons License
Iskenderun Technical University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@İSTE:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.