A modified energy management scheme to support phase balancing in grid interfaced photovoltaic/fuel cell system

Thumbnail

View/Open

Tam Metin / Full Text (5.028Mb)

Date

2021

Author

İnci, Mustafa
Aygen, Mehmet Selim

Metadata

Show full item record

Citation

İnci, M., Aygen, M.S. (2021). A modified energy management scheme to support phase balancing in grid interfaced photovoltaic/fuel cell system. Ain Shams Engineering Journal. https://doi.org/10.1016/j.asej.2020.12.018

Abstract

This paper presents improved energy management for grid-inverter of a hybrid photovoltaic (PV)/fuel cell (FC) energy system with unbalanced sensitive loads. In the system, unbalanced loads draw unbalanced currents at each phase and consume power from energy units at different levels. This condition makes the grid unbalanced, which cannot be compensated by a conventional energy management controller used in grid inverters. For this, a phase balancing control method is proposed in order to improve the grid quality under unbalanced loading conditions. The proposed method calculates power differentiation values based on multiple-frame αβ/dq transform instead of abc/dq transform in the conventional method. Thus, it eliminates negative & zero sequence components in addition to power flow control. Under unbalanced loading conditions, the proposed method removes the deficiency of the conventional energy management method which generates the symmetrical current references to trigger the switching elements of the inverter. In performance results, the system with unbalanced loads is tested for different case studies, which supply different power from energy units to grids. The results show that the proposed method provides power balancing at the grid-side and eliminates negative & zero sequence components at grid-side currents.

Source

Ain Shams Engineering Journal

URI

https://doi.org/10.1016/j.asej.2020.12.018
https://hdl.handle.net/20.500.12508/1796

Collections

  • Araştırma Çıktıları | Scopus İndeksli Yayınlar Koleksiyonu [1419]
  • Makale Koleksiyonu [78]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Instruction | Guide | Contact |

DSpace@İSTE

by OpenAIRE
Advanced Search

sherpa/romeo
Dergi Adı / ISSN Yayıncı

Exact phrase only All keywords Any

Başlık İle Başlar İçerir ISSN


Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeDepartmentPublisherCategoryLanguageAccess TypeİSTE AuthorIndexed SourcesThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeDepartmentPublisherCategoryLanguageAccess TypeİSTE AuthorIndexed Sources

My Account

LoginRegister

Statistics

View Google Analytics Statistics

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Guide|| Instruction || Library || Iskenderun Technical University || OAI-PMH ||

Iskenderun Technical University, İskenderun, Turkey
If you find any errors in content, please contact:

Creative Commons License
Iskenderun Technical University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@İSTE:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.